- Out-of-Stock
Schneider Electric (A9D17332) Circuit Breaker, Acti 9 iC60, 240 V, 32 A
Schneider Electric (A9D17332) Circuit Breaker, Acti 9 iC60, 240 V, 32 A
Circuit Breaker, Acti 9 iC60, 240 V, 32 A, 3 Pole Product Information Product Range: Acti 9 iC60 Voltage Rating VAC: 240V Current Rating: 32A No. of Poles: 3 Pole Insulation Voltage: 500VAC Main Range Acti 9 Product name Acti 9 iC60 RCBO Product or component type Residual current breaker with overcurrent protection (RCBO) Device short name IC60 RCBO Device application Distribution Poles description 3P Number of protected poles 3 [In] rated current 32 A Network type AC Trip unit technology Thermal-magnetic Curve code C Earth-leakage sensitivity 30 mA Earth-leakage protection time delay Instantaneous Earth-leakage protection class Type A Breaking capacity 10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 15 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2 Suitability for isolation No conforming to IEC 60947-1 Quality labels NF KEMA-KEUR VDE IMQ Complementary Device location in system Outgoer Network frequency 50 Hz [Ue] rated operational voltage 220...240 V AC 50 Hz Magnetic tripping limit 5...10 x In Residual current tripping technology Voltage independent [Ics] rated service breaking capacity 7500 A 75 % x Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 7.5 kA 50 % x Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2 Rated breaking and making capacity Idm 6000 A at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 Limitation class 1 conforming to EN/IEC 61009-2-1 [Ui] rated insulation voltage 500 V AC 50 Hz [Uimp] rated impulse withstand voltage 4 kV Surge current 250 A Contact position indicator No Control type Toggle Local signalling ON, OFF, fault trip Mounting mode Clip-on Mounting support DIN rail Comb busbar and distribution block compatibility Top or bottom: YES Bottom: biconnect 9 mm pitches 6 Height 86 mm Width 54 mm Depth 78 mm Net weight 334 g Colour White Mechanical durability 20000 cycles Electrical durability 10000 cycles Connections - terminals Tunnel type terminal top or bottom 1…35 mm² rigid Tunnel type terminal top or bottom 1…25 mm² flexible Tunnel type terminal top or bottom 1…25 mm² flexible with ferrule Wire stripping length 12 mm for top or bottom connection Tightening torque 2 N.m Earth-leakage protection Integrated Environment Standards EN/IEC 60947-2 EN/IEC 61009-2-1 IP degree of protection IP40 (distribution enclosure) conforming to IEC 60529 IP20 conforming to IEC 60529 Overvoltage category III conforming to IEC 60364 Electromagnetic compatibility 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1 Tropicalisation 2 Relative humidity 95 % at 55 °C Ambient air temperature for operation -25…40 °C Ambient air temperature for storage -40…70 °C